| PRODUCTION ENGINEERING MEASURE. CRYSTAL UNIT, TYPE CR-(XM-30)/U. |
NOV 1964 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The report includes a review of the technical problems encountered and an analysis of test results achieved in the Pilot Run. It consists of three parts: History of the PEM Study, Process Manual, and Quality Control Manual. Part I contains detailed descriptions and supporting data on problems encountered in the development of a suitable source of glass holders and sealing equipment, related crystal processing, test results achieved in the Pilot ... |
|
| PRODUCTION ENGINEERING MEASURE. CRYSTAL UNIT, TYPE CR-(XM-28)/U. |
JUL 1964 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The FINAL REPORT presents a condensed summary of all work accomplished on the PEM Contract from January, 1959 to July, 1964. The Summary includes a review of the technical problems encountered and an analysis of test results achieved in the Pilot Run. The report consists of three parts: History of the PEM Study, Process Manual and Quality Control Manual. Part I contains detailed descriptions and supporting data on problems encountered ... |
|
| 5 MC SINGLE SIDEBAND CRYSTALS. |
31 MAR 1964 |
|
| Authors:
Raymond F. Woolley; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The project is intended to develop a non-controlled crystal having a precision of frequency in the order of 5 pp 10 to the 6th power, a stability of 1 pp 10 to the 8th power per week - or better - - and a Q in excess of 500,000. Prior to this period, it was demonstrated that engineering samples could meet the requirements. The single obstacle which prevented submission at ... |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
MAR 1964 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | All frequency measurements are compared to the primary standard, which can be traced to the National Bureau of Standards. The system employed is discussed. The results of the tests performed on the preproduction samples are tabulated. (Author) |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
1964 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | A study was made of the comparative aging rates of glass vs. metal enclosed units. The intent was to establish, if possible, the contributing factors related to crystal unit aging. Control groups were divided so that identifical groups were enclosed in both glass and metal, using various types of mounting clips and bonding cements. The units were aged at 85C. All units were 30mc units. Because of the complexity involved ... |
|
| 5 MC SINGLE SIDEBAND CRYSTALS. |
31 DEC 1963 |
|
| Authors:
Raymond F. Woolley; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The report details results of fabrication of units prepared during the quarter, and indicates problems have been encountered in maintaining desired angles of orientation through the contouring operation. 'Q' in excess of 500,000 has been achieved with units finished with a 305 abrasive and plated with an evaporated aluminum film. Successful methods of achieving a mechanically strong bond using cement are also reported. Photographs and details of the aging equipment ... |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
DEC 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Initial results obtained from the limited production equipment are discussed, and problems encountered are described. Specification data sheets are furnished, which lists all details of the crystal design. (Author) |
|
| 5 MC SINGLE SIDEBAND CRYSTALS. |
30 SEP 1963 |
|
| Authors:
Raymond F. Woolley; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The requirements and previous literature which indicates that Q of 3 x ten to the 6th is possible at a frequency of 5 mc. To reach the desired Q, it is indicated that a plano-convex blank is necessary, together with evacuation of the unit in a glass holder. Maintenance of angle of orientation to =15 seconds of the Z-Z' will be necessary to achieve the desired change in frequency. Proposed ... |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
SEP 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Efforts concern establishment of a facility for the manufacture of crystal-units CR-(XM28)/U utilizing the HC-27/U all glass holder. Comparisons of results achieved using goldplated electrodes with those achieved using aluminum, are made. The same improvement in control of frequency change is noted when the film is annealed prior to sealing in glass. Final details of the limited production equipment were worked out and the equipment is described. A method for ... |
|
| CRYSTAL UNIT CR-(XM-30). |
SEP 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
|
| CRYSTAL UNIT CR-(XM-28)/U. |
JUN 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | The continuing program leading to the development of the production sealing equipment for Crystal Units in H C -27/U glass holder is reported, including the solution of problems of change of frequency during sealing. Results of subjecting bonding cements to high temperatures are reported. Also reported are plans for the aging studies to be performed under the development program and equipment to be used in making the aging measurements. (Author) ... |
|
| CRYSTAL UNIT (CR - XM-30)/U. |
JUN 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Continuing problems associated with the supply of Crystal Holders, HC-(XM-4)/U, are reported, as well as efforts to improve operation of the prototype limited production equipment. (Author) |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
MAR 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Efforts were continued on the establishment of a facility for the manufacture of crystal unit CR-CXM-28/U utilizing the HC-27/U all glass holder. The development of the production sealing equipment for Crystal Units in H C - |
|
| CRYSTAL UNIT CR-(XM-30)/U. |
MAR 1963 |
|
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Difficulties encountered with the recently received supply of miniature glass holders is reported together with a discussion of the differences in dimensions between the experimental and single service specification holders. Difficulties experienced in sealing the crystal units because of changes in frequency are reported. (Author) |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
DEC 1962 |
15 pages |
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Effort is presented on the manufacture of crystal units. The prototype glass sealing equipment is reported as well as results of preliminary tests of the sealing fixtures. Crystal blanks to be used in the Aging study have been prepared and de tails of the finishing techniques of the control groups are presented. (Author) |
|
| CRYSTAL UNIT CR-(XM-28)/U. |
30 SEP 1962 |
12 pages |
| Authors:
James M. Ronan; KEYSTONE CONTROLS CORP NEWARK N J
|
 | Efforts were continued on the manufacture of crystal unit CR-(XM-28). Attempts to obtain con sistently satisfactory seals of the HC-27/U type holder were unsuccessful. A design for a new holding fixture is shown, and a commercially available sealing machine is reported. Results indicate that the unglazed base is superior to the glazed in obtaining good seals of the glass parts. A method of cleaning Kovar is reported on, as well ... |
|