Helical magnetic flux compression generators (HFCGs) have been in use for about five decades. There remain limitations to their performance. Recently and for the first time, calculations of high accuracy of HFCG output have been made. The calculated results assume that there are no electrical breakdowns in the generator resulting in a decrease of flux delivered. It has been very difficult to build high performance generators within desired size constraints ...